Filtration apparatus

Filter

 Filter funnels VitraPOR®, Borosilicate glass 3.3

Robu

Borosilicate glass 3.3, with sintered disc filter as outlined below. Autoclavable....

 Biosart®100 monitors

Sartorius

Filtration unit for use with a Sartorius vacuum manifold or direct attachment to a special vacuum pump. Biosart ® 100 Monitors have been specifically designed for the microbiological testing of pharmaceuticals, food, beverages, water and other liquids. These sterile disposable units with built-in membrane filter and cellulose pad are ready to use. After filtration, just remove the 100ml funnel to convert the monitor into a petri dish. Culture media for wetting the pad are available in individually sterilised, convenient plastic ampoules. Biosart...

 Filter units, PES membrane, sterile

Th. Geyer

These bottle-top filter units are ideally suited for the separation or purification of samples which are contained in large volumes. The units are available with either 0.22 µm or 0.45 µm pore sizes and 3 different volumes (250, 500 and 1000 ml).
Features:

  • Bottle-top filter and reservoir bottle are included
  • Light weight and stable wall construction
  • Large knurls on the reservoir bottle cap for easy screwing
  • Wide bottle mouth for efficient pouring out
  • Volume graduation
  • Hose connector fits multiple diameters
  • Pyrogen-free
  • Membrane material: Polyethersulfone (PES)
...

 Buchner funnels, porcelain

Haldenwanger

To DIN 12905....

 Slotted sieve disc (perforated plate) DURAN®

DWK

Can be used in the 250ml capacity dismountable filter holder as a carrier for membrane and paper filters....

 Bottle Top Filters Nalgene™, PSU, without membrane

Nalgene

Reusable, PSU filter manifolds for fitting onto bottles with 33mm or 45mm screw neck diameters. Non-toxic. Robust body with removable membrane support plate. Suitable for pressure filtration up to 600mbar and vacuum filtration. With seal, cap and tubing adapter on lower half of the assembly. Autoclavable. Without membrane (47mm or 50mm diameter can be fitted)....

 DURAN® Filtering Flask with Glass Hose Connection, Erlenmeyer shape

DWK

Due to the heavy wall thickness the apparatus is vacuum-tight....

 Filter rings, rubber

Deutsch & Neumann

Natural rubber (NR). To hold filter funnels or crucibles....

 Filter Units, Cellulose Nitrate Membrane, sterile

Nalgene

White, cellulose nitrate membrane. Colour code: green. Gamma-irradiated sterile. Highest throughput rate for water and aqueous solutions, low extractables content. Surfactant-free. Lot number, catalogue number, membrane type, pore size and expiration date are printed on filter units, bottle tops and receivers for easy identification and lot traceability....

 Filter funnels, glass DURAN®, conical

DWK

Conical. Glass Type I / neutral glass as per USP, EP and JP. Autoclavable....

 Filter flasks, glass DURAN®

DWK

DIN 12476. ISO 6556. Erlenmeyer shape. Heavy wall, for vacuum use. With ground 17.5/26 socket for vacuum tubing with 15mm to 18mm external diameter. These filtering flasks fulfil the regulations of the "equipment and product safety regulations"....

 Filtering apparatus DURAN®

DWK

The DURAN ® filtering apparatus is made of high-quality borosilicate glass. Aside from glass, the medium only comes into chemical contact with PTFE. This means that the filtering apparatus can be used to filter virtually any chemical. Thanks to the PTFE disc holder, fritted glass discs of different porosities can be used in addition to the slit-sieve disc. This creates a wide application scope for filtration using filter paper, membrane filters (47mm) or simply using glass filters. Different porosities are available between 10µm and 160µm, which makes it possible to perform coarse and fine filtration in addition to analytical filtration. Furthermore, the filtering apparatus is suitable for the filtration of HPLC media, testing for bacterial contamination, residue analysis and the filtration of other media....

 Filter discs, DURAN®

DWK

With glass rim. For use in dismountable filter holders. Patented design. Filter discs must always be screwed in between two FKM rubber seals. Without top manifold, PP outlet funnel or seals....

 Filter funnels VitraPOR®, conical, borosilicate glass 3.3

Robu

With sintered disc filter....

 Adapters for filter crucibles, Duran®

DWK

Glass Type I / neutral glass as per USP, EP and JP. Autoclavable....

 Bottle Top Filters Nalgene™ Rapid-Flow™, PES Membrane, sterile

Nalgene

Filters securely screw onto glass media bottles with 33 mm or 45 mm neck sizes. Allows direct filtration of liquid into sterile glass media bottles.
Tight and secure thread connection for vacuum filtration, vacuum tubing to be connected onto tubing adapter of side-arm. Graduated. Certificate of quality included in each full case. Lot number, catalogue number, membrane type, pore size and expiration date are printed on filter units for easy identification and lot traceability....

 Discs for filter funnels, Buchner, HDPE

Kartell

Useful interface layer between filter paper and perforated Buchner plate. Avoids clogging of filter holes....

 Filter flasks, bottle shape, DURAN®

DWK

DIN 12476. ISO 6556. With PBT tubing connection and silicone (VMQ) seal. Heavy wall for vacuum use. These filtering flasks fulfil the regulations of the equipment and product safety regulations....

 Filter funnels, glass DURAN®

DWK

Glass Type I / neutral glass as per USP, EP and JP. Autoclavable....

 Vacuum or pressure filtration apparatus, Typ 16510, PC

Sartorius

For vacuum or pressure filtration up to 2 bar.
For ultra or sterile filtration.
With collecting bottle 250 ml.
For filter 47mm diameter filters....

 Adapters for filter crucibles, borosilicate glass 3.3

Robu

Borosilicate glass 3.3, autoclavable....

 Bottle Top Filters Nalgene™ Rapid-Flow™, SFCA Membrane, sterile

Nalgene

Tissue culture filters for screw fitting onto bottles with 33mm or 45mm neck diameters. With surfactant-free, cellulose acetate membrane (SFCA) and polystyrene (PS) housing. Gamma-irradiated sterile. Pyrogen-free. Non cytotoxic. Low-pressure filtration can be carried out directly into a suitable sterile bottle. Caution: Only use sterile bottles authorised for use in low pressure applications. Always wear protective equipment for low pressure procedures. The membrane is characterised by its low protein binding, good throughput rates and minimal clogging with negligible protein loss. Permanent, moulded graduations. Quick-disconnection tubing adaptor with cellulosic vent plug for tubing with an internal diameter of 6mm to 9mm. Lot number, catalogue number, membrane type, pore size and expiration date are printed on filter units for easy identification and lot traceability....

 Gooch crucibles, porcelain

Isolab

Made from porcelain with perforated bottoms. They need filter paper for filtering process....

 Rubber sleeves, EPDM

Deutsch & Neumann

For filter crucibles. Temperature resistant up to 150°C. Autoclavable....

 Vacuum filtration equipment, GV 025 series

Cytiva

  • funnel volume 60 ml
  • for filter 25 mm diameter
...

Add to shopping cart